PRIME NR v2.1
- Combination of ERS technology with solar loading, therefore high use of regenerative energy
- Application range ground in heating from 5 °C to 15 °C (water from 5 °C to 15 °C)
- With external air modul the PRIME can be used as air water heat pump
- Modular expandable, with cascading further performance rise possible
- High performance though inovative heating and cooling technology
- Can be used individually for different sources
- Long life expectancy though soft starting
- Phase sequencer monitoring integrated
- Fully hermetic compressor heat pump
- With alternative refrigerant R454B
- Standard gas monitoring system
- Standard with two gas sensors
- Remote monitoring via internet
- Maintenance friendly housing
- Standard motor protection
- Low GWP value of 466
- Few space required
PRIME NR v2.1
- ERS ground storage, deep borehole and air cooler
- different sources: air, ERS, ground, water
- performance from 65kW to 390kW (85kW to 510kW)
- for heating and cooling
- new construction and refurbishment
PRIME NR v2.1
Seasonal energy efficiency in heating
196 %
Efficiency class A+++
PRIME solo NR v2.1
- Combination of ERS technology with solar loading, therefore high use of regenerative energy
- Comfort control based on outside temperature with mixer and domestic hot water control
- High coefficient of performance through innovative heating and cooling technology
- Application range: ground temperature in heating from 5 °C to 15 °C
- Can be expanded by adding modules in cascade
- Can be used individually with different sources
- Phase sequencer monitoring integrated
- Standard with gas monitoring system
- With alternative refrigerant R 454B
- Remote monitoring via internet
- Standard with two gas sensors
- Maintenance friendly housing
- Extremely silent operation
- Standard motor protection
- Low GWP value of 466
- Few space required
PRIME solo NR v2.1
- ERS ground heat exchanger, boreholes, energy baskets, ground loop exchangers
- different sources: ERS, ground
- Power capacities: 25 kW, 45 kW and 65kW
- for heating and cooling
- new construction and refurbishment
PRIME solo NR v2.1
Seasonal energy efficiency in heating
196 %
Efficiency class A+++
PRIME solo NR WW v2.1
- Comfort control based on outside temperature with mixer and domestic hot water control
- High coefficient of performance through innovative heating and cooling technology
- Application range: source temperature in heating from 5 °C to 15 °C
- Can be used with gound water and surface water
- Can be expanded by adding modules in cascade
- Phase sequencer monitoring integrated
- Standard with gas monitoring system
- With alternative refrigerant R 454B
- Remote monitoring via internet
- Standard with two gas sensors
- Maintenance friendly housing
- Extremely silent operation
- Standard motor protection
- Low GWP value of 466
- Few space required
PRIME solo NR WW v2.1
- Ground water and surface water
- Power capacities: 30 kW, 55 kW and 85kW
- for heating and cooling
- new construction and refurbishment
PRIME solo NR WW v2.1
Seasonal energy efficiency in heating
260 %
Efficiency class A+++
PRIME solo HT v2.1
- Combination of ERS technology with solar loading, therefore high use of regenerative energy
- High temperature heat pump, designed for high source temperatures up to 30 °C
- Outside temperature controlled comfort controller with mixer and hot water control
- Can be used as booster heat pump in combination with LW heat pump
- High coefficient of performance due to innovative heating and cooling technology
- Can be used for water/water and heat recovery
- Can be extended at any time by cascading
- Application range source from 10 °C to 30 °C
- up to 70 °C heating flow temperature
- with alternative refrigerant R513 A
- Refrigerant safety group A1
- Remote monitoring via internet
- Integrated rotating field monitoring
- Motor protection switch as standard
- Maintenance friendly housing
- Low operating noise
- GWP refrigerant 631
PRIME solo HT v2.1
- High temperatue up to 70 °C
- Source: water
- Power capacities: 28 kW and 50 kW
- For heating
- For new construction and refurbishment
PRIME solo HT v2.1
LW 35/50/80 NR v2.2
- Due to integrated reversible refrigeration cycle suitable as air conditioner if necessary
- External temperature based e TALK controller with mixer and domestic hot water control
- Fully automatic operation for heating and cooling
- Air operating temperature 25 °C to 40 °C
- Modularly expandable through cascading
- Expandable through optional equipment
- Phase sequence integrated monitoring
- Fully hermetic compressor heat pump
- Utilizes external air as energy source
- Maintenance friendly housing
- Alternative refrigerant R454B
- Extremely silent operation
- Remote monitoring
LW 35/50/80 NR v2.2
- external air as energy source
- usable as an air conditioner
- for heating and cooling
- new construcion and refurbishment
LW 35/50/80 NR v2.2
Seasonal energy efficiency in heating
156 %
Clime middle
Efficiency class A++
LW 100/150 NR v2.2
- Due to integrated reversible refrigeration cycle suitable as air conditioner if necessary
- External temperature based e TALK controller with mixer and domestic hot water control
- Fully automatic operation for heating and cooling
- Air operating temperature 25 °C to 40 °C
- Modularly expandable through cascading
- Phase sequence integrated monitoring
- Fully hermetic compressor heat pump
- Utilizes external air as energy source
- With alternative refrigerant R454B
- Maintenance friendly housing
- Extremely silent operation
- Remote monitoring
LW 100/150 NR v2.2
- external air as energy source
- usable as an air conditioner
- for heating and cooling
- new construcion and refurbishment
LW 100/150 NR v2.2
Seasonal energy efficiency in heating
184 %
Clime middle
Efficiency class A+++
LW 14/20 v2.3
- External temperature based e TALK controller with mixer and domestic hot water control
- Remote monitoring (optional in EMM electrical cabinet)
- Fully automatic operation for heating and cooling
- Fully hermetic inverter compressor heat pump
- Air operating temperature 25 C to 43 C
- Modularly expandable through cascading
- Phase sequence integrated monitoring
- Utilizes external air as energy source
- With natural refrigerant R290
- Extremely silent operation
- Low GWP value of 3
LW 14/20 v2.3
- external air as energy source
- for heating and cooling
- new construcion and refurbishment
LW 14/20 v2.3
Seasonal energy efficiency in heating
185 %
Clime middle
Efficiency class A+++